CPX-E-EC (4080498) bus module

OT-FESTO072237

Exemplary representation: CPX-E-EC
pcs
{{ $t('shop.display.artikel.hinweis_alternative') }}
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Dimensions W x L x H 42.2 mm x 125.8 mm x 76.5 mm
Pitch dimension [mm] 18,9
Diagnosis via LED EtherCAT Error,
EtherCAT RUN,
Modify,
Voltage supply electronics/sensors,
Voltage supply Last,
System error,
Connection status
Diagnosis via bus Under-voltage,
Wire break,
Short circuit,
Parametering error,
upper limit value not held,
over-temperature,
lower limit value not held
Module parameter Bundling channel alarms,
Diagnosis under-voltage,
Channel alarms under-voltage
Voltage supply, connection type Multi tube holder
Voltage supply, connection technology Spring tension clamp
Voltage supply, number of poles/wires 4
Voltage supply, conductor cross-section [mm²] 0.2 to 1.5
Voltage supply, information on conductor cross-section 0.2 - 2.5 mm² for flexible conductor without wire end sleeve
Permission RCM mark
CE certificate (see declaration of conformity) to EU EMC directive
Oscillation strength Transport use test with severity level 1 to FN 942017-4 and EN 60068-2-6
Shock resistance Shock test with degree of severity 1 to FN 942017-5 and EN 60068-2-27
Corrosion resistant class KBK 0 - No corrosion stressing
Bearing temperature [°C] -20 to 70
Relative humidity 95 %,
Not condensing
Protect against direct and indirect contact Funktionskleinspannung mit sicherer Trennung (PELV)
Protection category IP20
ambient temperature [°C] -5 to 50
Information about ambient temperature -5 - 60 °C with vertical installation
Product weight [g] 145
Max. address volume outputs [Byte] 64
Fastening type With Slot rail
Material information LABS containing materials included,
RoHs compliant
Housing material PA
Intrinsic power input operating voltage electronics/sensors typically 64 mA
Nominal operating voltage DC electronics / sensor [V] 24
Permitted voltage oscillations electronics/sensors ± 25 %
Max. address volume inputs [Byte] 64
Power blackout bridging [ms] 20
Configuration support ESI file
Max. number of modules 10
System parameter Force mode,
Diagnosis memory,
Failsafe reaction,
System start
Max. power supply [A] 8
Voltage supply, function Electronics and sensors
Information about outputs 62 Byte mit E/A-Diagnose-Interface,
64 Byte ohne Diagnose,
64 Byte mit Statusbits
Information out inputs 62 byte with I/O diagnosis interface,
63 byte with status bits,
64 byte without diagnosis
Fieldbus interface, galvanically separated yes
Fieldbus interface, transfer rate 100 Mbit/s
Fieldbus interface EtherCAT
Fieldbus interface, connection type 2x socket
Fieldbus interface, connection technology RJ45
Fieldbus interface, number of pins / wires 8
Fieldbus interface, report EtherCAT
Feldbus-Schnittstelle, Max. Adressvolumen Eingänge [Byte] 64
Feldbus-Schnittstelle, Max. Adressvolumen Ausgänge [Byte] 64
OT-FESTO072237
{{ $t('shop.all.gewicht') }} 145 g / pcs
{{ $t('shop.display.artikel.zollwarennummer') }} 85176200
{{ $t('shop.all.hersteller') }} Festo
{{ $t('shop.all.dokumente') }}

 
{{ $t('shop.all.unverbindliche_richtwerte') }}
{{ $t('shop.all.spaetbestellservice') }}
{{ countdownAsString }} {{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.spaetbestellservice.hinweis') }}

{{ $t('shop.all.wochenendversand') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.wochenendversand.hinweis') }}

An error has occurred!

An error has occurred, please reload this page and try again.